Column Design

Project:www.sefindia.org
Component:Miscellaneous
Category:task
Priority:normal
Assigned:pradeep_kumarr
Status:active
Description

The Steel Column is designed considering the loading capacity and L/R ratio, where L = Effective length and R = Radius of gyration. If Column is provided with web Stiffener plate, does it have any influence on Radius of Gyration of the Section and hence the L/R ratio?

Updates

#1 submitted by fazilat.zaidi on Thu, 04/21/2011 - 12:15

Dear friend,

Providing stiffness does not have any impact on effective length.