I am designing a triangular tower of 60m.
Which method i should use (static, gust factor, dynamic), which code has to be followed for steel design (is800-2007 or 802)

Kindly, provided your valuable comments and any references/literature if possible.

Updates

#1 submitted by rivas on Wed, 06/08/2011 - 13:20

hi,
sory for the late reponc yu can go with both IS 802,IS 800 & IS 875,. IS 802 is mainly for transmission line but yo can take the design formula from IS 802 & wind should be calculated as per IS 875, there is condition in IS 875 cls no; 7, Please check that and finalize wether you required dynamic analysis.
i hope this information is useful.